. . .when I get serious about finishing up electrical work here at twc central.
*profound sigh*
I do so very much dislike doing electrical work, but the only electrician I really trust here in America’s Third County retired a couple of years ago, and I really, really, really don’t want to pay someone to just screw things up, so that leaves me, my “consultant” (“Hey, X, can you tell me what to do/where to go for parts/etc., for such and so?”) and my several references on electrical work, codes, etc.
See, there are several ESSENTIAL circuits. Some I’ve already reworked, and they’re OK, but there is one seriously, majorly [messed up] circuit that serves stuff all over the house in ways that make no rhyme or reason that I’ve been putting off simply because it is the single weirdest electrical circuit I’ve ever run across. It serves parts of serveral rooms and one room entirely–the small room I have used as an office that is now pretty much simply a computer junk room and place with my most comfy chair for sitting at a computer.
(Yeh, yeh, I know, whine, whine, whine.)
Well, that circuit decided today was the day to go crazy. Dead. Live. Dead again. No, the circuit breaker doesn’t pop. It’s the live bus bar in the main box. *sigh* Yeh. Best solution is simply to replace the main service panel. *groan* I do NOT want to do that. Second best: call the manufacturer and order a new bus bar. Now, while that’s nearly the cost of a completely new circuit panel and still involves working around the live mains, I can do that. (Good insulation all over, including properly insulated tools, gloves, shoes, etc., then terminating the live mains with appropriately-sized insulators; still a PITA and still a bit scary. *shrugs* I have life insurance. :-)) But that, of course, will still leave me with rewiring to do, since circuits wired by a jackleg electrician and added to later by someone’s retarded pet monkey still need to be cleaned up (*cough* rewired completely *cough*).
Ah, well, in th meantime, I can bring in those three (or four–there is room in the box) circuits someone added to the house in a box outside about 30 years or so ago (going by the manufacture date of the circuit panel outside). . . coming straight off the mains! *sigh* I suppose I could cut off two of the rooms on this bad circuit and use one circuit apiece from the outside box for them. That’d (temporarily, in a hash-up sort of way) solve a world of ills. Another for an appliance circuit that I think is overloaded, although it’s never had any problems. I could almost do that recycling the conduit that’s outside, although I’d want to use new wiring.
Looks like my Spring task list has pretty well filled up, cos I do electrical work v e r y s l o w l y.